A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX540 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX540   Description / Specification:    
EXTECH INSTRUMENTS EX540 True RMS Wireless Digital Multimeter and Datalogger

The Extech EX540 is a True RMS wireless digital multimeter and datalogger offers wireless data streaming to a laptop or PC for datalogging or real-time monitoring. The EX540 transmits real-time data for monitoring, trending and analysis. In addition to wireless datalogging, the EX540 can log up to 9,999 readings internally and also reads voltage, current, resistance, capacitance, frequency (with dual-range sensitivity for electrical and electronic work), duty cycle, continuity, diode testing (2.8 volts), and even temperature (using its Type K thermistor bead probe). It features 0.06 percent accuracy that is a tough-to-beat, and a CAT IV-600-volt overvoltage safety rating, protecting users even on outdoor wiring. Several one-button data functions include minimum/maximum, relative, hold, and peak hold as well as selectable auto-ranging or manual-ranging.
Specifications.

Display Counts: 40,000 count.
Basic Accuracy: 0.06%.
DC/AC Voltage: 0.01mV to 1000VDC; 0.01mV to 1000VAC.
DC/AC Current: 0.01μA to 20A.
Resistance: 0.01Ωto 40MΩ.
Capacitance: 0.001nF to 40mF.
Frequency (electrical): 40Hz to 400Hz.
Frequency (electronic): 0.001Hz to 100MHz.
Temperature: -50 to 1382°F (-45 to 750°C).
Duty Cycle: 0.1 to 99.90%.
Diode/Continuity: Yes.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your EXTECH INSTRUMENTS EX540 CALIBRATION and/or EXTECH INSTRUMENTS EX540 True RMS Wireless Digital Multimeter and Datalogger REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: